Approved Document B (Part B) – Fire Safety Explained Simply

Approved Document B is the official government guidance for fire safety under Part B of the Building Regulations in England.

It explains how buildings should be designed and constructed so that people can escape safely if there is a fire.

Approved Document B does not replace the law. It provides practical guidance on how to meet the legal fire safety requirements.

The official version of the document is published by the UK Government and can be accessed via the Approved Document B (Fire Safety) on GOV.UK

What Is Approved Document B? #

Approved Document B is statutory guidance issued by the government.

It supports Part B of the Building Regulations 2010.

It explains how to design and build a structure so that:


  • People can escape safely
  • Fire and smoke spread is limited
  • The structure remains stable for a period of time
  • Firefighters can access the building

What Does Approved Document B Cover? #

Approved Document B focuses on four main areas of fire safety.

Means of Escape #

This section ensures occupants can leave a building safely in the event of a fire.

  • Number of exits
  • Travel distances
  • Protected stairways
  • Corridor protection
  • Emergency lighting
  • Fire alarm systems

Internal Fire Spread #

This section deals with preventing fire and smoke spreading within the building.

  • Fire-resistant walls and floors
  • Compartmentation
  • Fire doors
  • Fire stopping
  • Surface linings

External Fire Spread #

This section addresses the risk of fire spreading to neighbouring buildings.

  • External wall materials
  • Cladding systems
  • Roof coverings
  • Boundary distances
  • Openings near property lines

Access for Firefighters #

This section ensures the fire service can reach and operate safely within the building.

  • Fire appliance access
  • Firefighting shafts
  • Dry risers
  • Wet risers
  • Firefighting lifts (for taller buildings)

Who Does Approved Document B Apply To? #

Approved Document B applies when carrying out building work such as:

  • New construction
  • Extensions
  • Conversions
  • Material alterations
  • Changes of use

Even small residential projects can trigger Part B requirements if they affect escape routes or fire separation.

Is Approved Document B Law? #

No.

The Building Regulations are the law.

Approved Document B is guidance that shows one way of complying with those legal requirements.

You may follow the guidance directly or use a fire-engineered alternative solution, provided Building Control accepts it.

Volume 1 vs Volume 2 – What’s the Difference? #

Volume 1 – Dwellings #

Applies to houses and flats.

Covers escape windows, smoke alarms, protected stairways and fire separation between residential units.

Volume 2 – Buildings Other Than Dwellings #

Applies to offices, shops, warehouses, schools, care homes and industrial buildings.

These buildings often have more complex requirements due to occupancy levels and building size.

Why Approved Document B Matters #

If fire safety is not designed correctly:

  • Occupants may not escape safely
  • Fire can spread rapidly
  • Projects may fail Building Control inspection
  • Remedial work may be required
  • Liability risks increase

Approved Document B sets minimum safety standards to reduce these risks.

Summary #

Approved Document B is the government’s practical guide to meeting fire safety requirements under Part B of the Building Regulations in England.

Anyone designing or carrying out building work that affects fire safety should consider its guidance.

For the latest version, refer to the official government publication:

Approved Document B (Fire Safety) on GOV.UK