One of the most common specification questions we receive is:
“What thickness of glass do I need to use with the Skyforce system?”
The answer depends on one key factor:
The width (span) of the opening you are guarding.
In simple terms:
- Smaller spans can use thinner glass
- Wider spans require thicker glass
This ensures the system continues to meet the horizontal line load requirements for guarding under BS 6180:2011.
How Glass Thickness and Span Are Related #
In frameless glass guarding systems such as Skyforce, the glass panel itself forms the primary structural barrier.
As the width of the glass panel increases, the panel becomes more flexible when horizontal loads are applied.
To maintain the required structural performance, thicker laminated glass is required for wider spans.
Conversely, when spans are smaller, thinner glass constructions can be used safely while still meeting the required load classifications.
Skyforce Glass Thickness and Maximum Spans #
The Skyforce system has been tested using toughened laminated safety glass in several standard thicknesses.
The maximum certified spans vary depending on the glass thickness and fixing type.
| Glass Thickness | Skyforce-Top Max Width | Skyforce-Side Max Width |
|---|---|---|
| 13.52mm toughened laminated | 1100mm | 1200mm |
| 17.52mm toughened laminated | 1700mm | 1500mm |
| 21.52mm toughened laminated | 3000mm | 2600mm |
These values represent the maximum certified glass widths for each configuration.
Choosing the Correct Glass Thickness #
When specifying a Skyforce Juliet balcony, the process is usually straightforward:
- Measure the clear structural opening width
- Select the glass thickness capable of spanning that width
- Ensure the chosen configuration remains within the certified maximum span
For example:
- A 1000mm opening could use 13.52mm laminated glass
- A 1400mm opening would typically require 17.52mm laminated glass
- A 2500–3000mm opening would require 21.52mm laminated glass
This approach ensures the system performs correctly while remaining within tested and certified limits.
Why Laminated Glass Is Always Used #
Skyforce systems always use toughened laminated glass, rather than single toughened panels.
This construction consists of:
- Two toughened glass panels
- Bonded together with a structural interlayer
Toughened laminated glass is essential for guarding applications because:
- If one pane breaks, the interlayer helps retain the barrier
- It prevents dangerous glass fallout
- It maintains residual structural integrity
This is why toughened laminated glass is the standard specification for balustrades and Juliet balconies.
Always Design Within Tested Limits #
The span values shown above are based on third-party accredited testing.
When specifying Skyforce systems, it is important to ensure that:
- The glass span does not exceed the certified maximum width
- The correct glass thickness is selected for the opening
- The system is installed in accordance with the tested configuration
Working within these limits ensures the system performs as intended and complies with the relevant standards.